Ubidots receives Myriota FlexSense and AssetHawk messages through an HTTP destination in Myriota Device Manager. Assign the destination to your devices, and each device appears in Ubidots on its first message, already decoded: named variables, units, its position on the map, and the time the device took each reading.
You do, in Myriota Device Manager | Ubidots does, on the first message |
Create an HTTP destination with the Ubidots URL | Creates one device per Myriota Terminal ID |
Assign the destination to your devices | Decodes the payload: FlexSense firmware presets or your own struct, AssetHawk location and Bluetooth messages |
| Names the known variables, sets their units and icons, and sets the device location |
| Stores each value at the device's reading time, so late messages land in the right place |
There is nothing to create in Ubidots: no devices, no decoder, no Terminal ID mapping.
Requirements
Myriota FlexSense or AssetHawk devices registered in Myriota Device Manager.
A Device Manager user that can create destinations and edit devices.
An Ubidots account on industrial.ubidots.com, with room on your plan for one Ubidots device per Myriota device, and your Ubidots token. No account yet? Start a free trial.
How the data gets to Ubidots
Device | Route | Payload Ubidots receives |
AssetHawk | /assethawk | JSON, already decoded by Myriota |
FlexSense | /flexsense | Raw bytes; the URL sets the layout |
myriota.ubidots.com keeps no copy of your token: each delivery carries it, and the data goes only to the account that owns it. Prefer a token used only for Myriota, so revoking it affects nothing else.
Try it in one minute, without a device
This posts a sample AssetHawk location message straight to Ubidots, the way Myriota would. Replace YOUR_UBIDOTS_TOKEN and run it in a terminal:
NOW=$(date +%s)
cat > assethawk-test.json <<EOF
{"Data": "{\"Packets\":[{\"TerminalId\":\"test-assethawk\",\"SerialNumber\":\"TEST\",\"Timestamp\":${NOW}000,\"Value\":[{\"type\":1,\"sequence_number\":1,\"reason\":0,\"flags\":0,\"time\":${NOW},\"latitude\":-34.9285,\"longitude\":138.6007,\"elevation\":48,\"temperature\":23.5,\"battery_voltage\":3.6}]}]}"}
EOF
curl -s -X POST 'https://myriota.ubidots.com/assethawk?token=YOUR_UBIDOTS_TOKEN' --data @assethawk-test.json
The response shows "forwarded":1, and AssetHawk TEST appears in Devices → Devices with nine variables, including its position. Delete it when you're done.
1. Build the destination URL
AssetHawk
https://myriota.ubidots.com/assethawk?token=YOUR_UBIDOTS_TOKEN
Nothing else to set. Myriota decodes AssetHawk messages before it delivers them.
FlexSense
A FlexSense message is a packed struct whose layout depends on the device firmware, so the URL names the firmware. The presets match Myriota's reference apps v1.6.0.
Firmware on the device | Myriota reference app | Add to the URL |
Tracker (factory default) | 001_tracker | nothing |
4-20mA sensor | 002_sensor_4-20ma | &firmware=4-20ma |
Pulse counter | 003_pulse_counter | &firmware=pulse-counter |
Your own firmware | — | &fields=… (see Custom FlexSense firmware) |
https://myriota.ubidots.com/flexsense?token=YOUR_UBIDOTS_TOKEN&firmware=4-20ma
A wrong firmware choice decodes without an error. Myriota pads messages to 20 bytes, so any layout reads them. A Tracker message read as Pulse Counter, for example, turns 23.45 °C into a pulse count of 2345. |
Each destination has one URL, so devices that run different firmware need separate destinations, for example Ubidots Tracker and Ubidots 4-20mA.
2. Create the HTTP destination
In Myriota Device Manager, select Destinations in the left menu and click + Create.
In New Destination, set Label to a name such as Ubidots, Type to HTTP, and URL to the URL from step 1.
Click Create.
3. Assign the destination to every device
A destination receives nothing until it's assigned to a device. Creating it isn't enough. This is the most common reason no data reaches Ubidots. |
Select Devices and open the device.
Click the + next to Destination/s, then + Add Destination.
Select the destination you created in step 2.
Repeat for each device. A device can have several destinations and each one gets every message, so your current platform keeps receiving data while you try Ubidots.
Assign a fleet with the Myriota Cloud API
The bind endpoint takes one device per call, so loop over the IDs: Module IDs for FlexSense, ICCIDs for AssetHawk. The destination ID is in the Id column of Destinations. For the API token, select Tokens in Device Manager and click Create; see Myriota's Cloud APIs guide.
DEST=YOUR_DESTINATION_ID
MYRIOTA_TOKEN=YOUR_MYRIOTA_API_TOKEN
for id in 89883380001234567890 89883380001234567891; do
curl -s -X POST "https://api.myriota.com/v1/destinations/$DEST/modules" \
-H "Authorization: $MYRIOTA_TOKEN" -H "Content-Type: application/json" \
-d "{\"Items\":[{\"Id\":\"$id\"}]}"
done
Each response lists the device Id, with an ErrorMessage if that binding failed.
4. Check the data in Ubidots
Go to Devices → Devices. The device appears with its first message, which comes at its next scheduled report plus satellite delivery time. The FlexSense factory firmware reports four times a day.
| FlexSense | AssetHawk |
Myriota identifier (Terminal ID) | Module ID | SIM ICCID, not the serial number on the label |
Ubidots device API label | Module ID, lowercase | ICCID |
Ubidots device name | FlexSense <Module ID> | AssetHawk <Serial Number> |
If a device with that API label already exists in Ubidots, the data goes into it.
Open the device to see its variables, their units and its position.
Test a FlexSense destination from Device Manager
In Device Manager, select Devices and click the Test Destinations icon on a FlexSense assigned to the destination.
Enter the test message for its firmware and click OK.
Firmware | Test message | Expected in Ubidots |
Tracker | 010000000000000000000000002909100e | Temperature 23.45 °C, Battery Voltage 3.6 V |
4-20mA | 010000000000000000000000002909e02e100e | Temperature 23.45 °C, Sensor Current 12 mA, Battery Voltage 3.6 V |
Pulse Counter | 010000000000000000000000002a00100e | Pulse Count 42, Battery Voltage 3.6 V |
Each also sets Sequence Number to 1 and is stored at the time Myriota captured it. None carries a position, so the device doesn't move on the map. If the device has other destinations, they receive the test too. To send a test again, change the first two characters, for example to 02.
AssetHawk
Device Manager's test can't produce an AssetHawk message: Myriota turns arbitrary data into an "unable to decode" error, which adds nothing in Ubidots. Use the one-minute test above, or wait for the device's next report.
Variables
FlexSense
API label | Name | Unit | Tracker | 4-20mA | Pulse Counter |
position | Position: sets the device location. Its value is always 1; lat and lng are in its context | — | ✓ | ✓ | ✓ |
temperature | Temperature, inside the device | °C | ✓ | ✓ |
|
battery_voltage | Battery Voltage | V | ✓ | ✓ | ✓ |
sensor_current | Sensor Current | mA |
| ✓ |
|
pulse_count | Pulse Count | — |
|
| ✓ |
sequence_number | Sequence Number: message counter, 0–255, then restarts | — | ✓ | ✓ | ✓ |
AssetHawk location messages
API label | Name | Unit | Notes |
position | Position | — | Sets the device location. Not written when the fix is stale or 0, 0 |
temperature | Temperature | °C |
|
battery_voltage | Battery Voltage | V |
|
elevation | Elevation | m |
|
message_reason | Message Reason | — | AssetHawk's reason code, 0–7 |
tampered | Tampered | — | 0 or 1, from flags bit 2 |
gps_stale | GPS Fix Stale | — | 0 or 1, from flags bit 1: the position repeats the last known fix |
bad_orientation | Bad Orientation | — | 0 or 1, from flags bit 0 |
sequence_number | Sequence Number | — | Counter for location messages |
Numeric fields that newer AssetHawk firmware adds to location messages are passed through under their own names.
AssetHawk Bluetooth messages
API label | Name | Unit | Notes |
ble_<mac>_rssi, for example ble_aabbccddeeff_rssi | Beacon AA:BB:CC:DD:EE:FF RSSI | dBm | One variable per beacon. The value's context holds address, protocol, data (raw beacon payload) and sequence_number |
Bluetooth and location reports are separate messages, each with its own timestamp.
How Ubidots handles the data
Situation | What happens |
Reading time | Ubidots uses the device's own time. It uses Myriota's capture time instead when the device clock reads before 2020 or more than 24 hours ahead, when custom firmware has no timestamp field, and for Bluetooth messages, whose time counts from boot |
Several variables in one message | They share one timestamp, so they line up in charts and exports |
Late or out-of-order delivery | Each value is stored at its reading time |
Duplicate satellite receptions | Myriota removes duplicate UltraLite receptions before delivery |
Several messages in one delivery | Each is processed on its own, for one or several devices |
No GPS fix (0, 0) | Position isn't written; the other variables are |
Padding after the FlexSense struct | Ignored |
A message that can't be decoded | Skipped; the rest of the delivery is processed |
Control Messages (downlink) | Not supported: the integration is uplink only |
Custom FlexSense firmware: fields=
FlexSense firmware sends its message as a packed C struct. Add &fields= to the URL and list the struct's members in order as name:type, separated by commas.
Type | C type | Bytes |
u8 / i8 | uint8_t / int8_t | 1 |
u16 / i16 | uint16_t / int16_t | 2 |
u32 / i32 | uint32_t / int32_t | 4 |
u64 / i64 | uint64_t / int64_t | 8 |
f32 / f64 | float / double | 4 / 8 |
Little-endian, like the FlexSense. Append be for big-endian, for example u16be.
/N divides and *N multiplies, for example level:u16/10. Write 1e7, not 1e+7: a URL turns + into a space.
Reserved names: timestamp (Unix seconds, used as the reading time), lat and lng (degrees; together they set the device position), and _ (read the member and discard it).
Any other name becomes a variable: lowercase letters, numbers, _ and -, each name used once. The names in the variables tables, such as temperature or battery_voltage, get their unit and icon automatically; set the others in Ubidots.
Firmware that sends this struct:
struct {
uint8_t seq;
uint32_t time; // Unix seconds
int32_t lat; // degrees × 1e7
int32_t lng; // degrees × 1e7
uint16_t level_dm; // decimetres
} __attribute__((packed));uses this URL, which creates the variables seq and level (in metres) and sets the device position:
https://myriota.ubidots.com/flexsense?token=YOUR_UBIDOTS_TOKEN&fields=seq:u8,timestamp:u32,lat:i32/1e7,lng:i32/1e7,level:u16/10
Check a fields= string before you assign it
Post an empty delivery to the URL. It writes nothing to your account.
curl -s -X POST 'https://myriota.ubidots.com/flexsense?token=YOUR_UBIDOTS_TOKEN&fields=seq:u8,timestamp:u32,lat:i32/1e7,lng:i32/1e7,level:u16/10' \
-d '{"Data":"{\"Packets\":[]}"}'
A valid layout returns 200 with {"firmware":"custom","received":0,…}. An invalid one returns 400 with the reason, for example Unknown type "u17" in "level:u17". This check doesn't validate the token.
Token in a header instead of the URL
Device Manager's form only takes a URL, so by default the token is part of the destination URL that every Device Manager user sees. To move it to a header, set it with Myriota's Cloud API, then remove ?token= from the destination URL.
PUT https://api.myriota.com/v1/destinations/YOUR_DESTINATION_ID/headers
Authorization: YOUR_MYRIOTA_API_TOKEN
Content-Type: application/json
{"X-Auth-Token": "YOUR_UBIDOTS_TOKEN"}
An X-Auth-Token header wins over ?token=, so data keeps flowing while you switch.
The header keeps the token out of the URL, not out of the Myriota account: API users of the account can still read it.
To change tokens, update the header or the URL. The next delivery uses the new token.
Troubleshooting: why is no data reaching Ubidots?
Symptom | Cause | Fix |
No device in Ubidots | Destination not assigned, no report yet, or a wrong token | Assign it (step 3); wait for the next scheduled report; check the token in the URL, with no spaces |
No device, and the destination is assigned | Wrong route (a FlexSense on /assethawk or an AssetHawk on /flexsense), or fields= describes more bytes than the device sends | Use the route for the device (step 1); fix fields= so it matches the struct |
Some devices never appear | Your Ubidots plan's device limit is reached | Raise the limit or delete unused devices |
FlexSense values look wrong | The URL's firmware doesn't match the device, or fields= misses a member | Fix firmware= (step 1), or list every struct member in order with its type |
A second device for the same AssetHawk | Its SIM ICCID changed, for example after a SIM swap; the serial number didn't | Keep the old device for its history, or delete it |
Device not on the map | No GPS fix (0, 0), or an AssetHawk stale fix | The other values still arrive. Give the device a clear view of the sky |
Gaps in Sequence Number | A message was lost or is still in transit | Late messages fill in at their reading time |
Responses from myriota.ubidots.com
Code | Meaning |
200 | Delivery processed. The body counts received, forwarded, duplicates, invalid and failed messages |
400 | Invalid firmware= or fields=, or not a Myriota delivery. The body gives the reason |
401 | Token missing, or rejected by Ubidots |
502 | Ubidots couldn't store a value |
Myriota retries any response other than 2xx, with growing delays between attempts.
FAQ
Do I have to create devices or variables in Ubidots first?
No. Each device is created on its first message, with its variables. A device you created beforehand with the same API label, the Terminal ID in lowercase, receives the data instead.
Can I keep sending data to my current platform?
Yes. A Myriota device can have several destinations, and each one gets every message. Add the Ubidots destination next to the existing one.
Can Ubidots send Control Messages to the device?
No. The integration is uplink only. Send Control Messages from Myriota Device Manager or Myriota's Cloud API.
Which Myriota devices does this cover?
FlexSense with Myriota's Tracker, 4-20mA or Pulse Counter reference firmware, FlexSense with custom firmware described in fields=, and AssetHawk location and Bluetooth messages. For another Myriota device, write to us through the chat.
Next steps
Alerts: Events on Battery Voltage, Tampered or GPS Fix Stale, an inactivity event for a device that stops reporting, or a geofence on its position.
Maps: a Map widget for the location of the whole fleet.
No account yet? Start a free trial and run the one-minute test above.